RECOMMENDED POWER CONFIGURATIONS
1. Liftgate, pump box, and battery box are typically installed
on trailers as shown in FIG. 59-1.
RECOMMENDED LIFTGATE & BATTERY BOX
INSTALLATION ON TRAILER
FIG. 59-1
NOTE: Make sure the power unit for the Liftgate, and all batteries on the vehicle
used as the power source, are connected correctly to a common chassis
ground.
LIFTGATE
BATTERY BOX,
TYPICAL LOCATION
PUMP BOX
150 AMP
CIRCUIT
BREAKER
200 AMP
CIRCUIT
BREAKER
GROUND
CABLE
POWER
CABLE
TRACTOR (REF)
MASTER
DISCONNECT
SWITCH
STEP 10 - RUN CHARGE LINES
CAUTION
!
Never route an energized wire. Make sure battery is disconnected. Always route
electrical wires clear of moving parts, brake lines, sharp edges and exhaust
systems. Avoid making sharp bends in wiring. Attach securely. If drilling is nec-
essary, rst check behind the drilling surface so you do not damage any fuel
lines, vent lines, brake lines or wires.