81
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
2. As platform is unfolding, check for
interference from the connector
bar side bracket as it slides into
the stop block (FIG. 81-1A).
FIG. 81-1
APPROX. 10”
REAR VIEW OF LH RUNNER
FIG. 81-1A
CONNECTOR BAR SIDE
BRACKET
STOP
BLOCK
INTERFERENCE
1. To check for interference
between platform connector
bar side bracket and stop block
(FIG. 81-1A), lower columns to
approximately 10” above the
ground, then begin to unfold
platform (FIG. 81-1).
STEP 17 - CHECK CLEARANCE OF CONNECTOR
BAR SIDE BRACKETS & STOP BLOCKS