65
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
7. Remove nut and washer
from unused terminal on
200 amp circuit breaker
(FIG. 65-1). Then, connect
red (+) cable to the termi-
nal. Reinstall and tighten
nut.
8. Remove nut from negative (-)
battery terminal (FIG. 65-1).
Then, connect black (-) cable
to negative (-) battery termi-
nal. Reinstall and tighten nut.
STEP 11 - CONNECT BATTERIES TO LIFTGATE - Cont’d
RED (+) CABLE
TO PUMP BOX
CHARGE LINE
FROM
VEHICLE BATTERY
BLACK (-) CABLE
TO PUMP BOX
150 AMP
CIRCUIT
BREAKER
NEGATIVE (-)
TERMINAL
BLACK (-)
CABLE
BATTERY
NUT
CONNECTING RED & BLACK CABLES
AND CHARGE LINE
FIG. 65-1
RED (+)
CABLE
200 AMP
CIRCUIT
BREAKER
9. Remove nut and washer
from unused terminal on
150 amp circuit breaker
(FIG. 65-1). Then, connect
charge line to the terminal.
Reinstall and tighten nut.