69
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
4. Lower (DOWN) the platform to 10”
above ground level using the toggle
switch settings shown in FIG. 69-1.
LOWERING PLATFORM
FIG. 69-1
STEP 13 - OPTIMIZE HYDRAULIC FLUID LEVEL -
Continued
DOWN
5. Raise (UP) the platform to about
6” below bed height using toggle
switch setting shown in FIG.
69-2.
RAISING PLATFORM
FIG. 69-2
UP
GROUND
10”