110
BIT3: DC bus voltage (V)
Tens place of LED:
BIT0: Running line speed (m/s)
BIT1: Preset line speed (m/s)
BIT2: Analog closed loop
feedback (%)
BIT3: Analog closed reference
(%)
Hundreds place of LED:
BIT0: AI1 (V)
BIT1: AI2 (V)
BIT2: AI3 (V)
BIT3: Terminal status (without
unit)
Note: The default display shall be
set frequency when all the
parameters are 0
P16.03
Line speed
coefficient
Line speed
coefficient
0.1~999.9%
VF-PG:
Line speed = mechanical rotating
speed × P16.03
Preset line speed = Preset
rotating speed × P16.03
VF-NPG:
Line speed = operation frequency
× P16.03
Preset line speed = Preset
frequency × P16.03
Non-VF:
Line speed = measured/estimated
rotating speed × P16.03
Preset line speed = Preset
frequency × P16.03
0.1% 1.0% ×
P16.04
Rotating
speed
display
coefficient
Rotating
speed
coefficient
0.1~999.9%
VF-PG:
Running rotating speed =
mechanical rotating speed ×
P16.04
Preset rotating speed = Preset
rotating speed × P16.04
VF-NPG:
Running rotating speed = running
frequency × motor rated rotating
speed/motor rated frequency ×
P16.04
Preset rotating speed = Preset
frequency × motor rated rotating
speed/motor rated frequency ×
0.1% 100.0% ×