109
P15.06
Reserved
function 2
for user
Reserved
function 2 for
user
0~65535 1 0 × √ ○
Group P16: Keyboard display setting parameters
P16.00
LED display
parameter
selection
1 when
running
Running
display 1
Binary setting:
0: No display; 1: Display
Unit place of LED:
BIT0: Output frequency (Hz)
BIT1: Preset frequency (Hz
flashing)
BIT2: Output current (A)
Tens place of LED:
BIT0: Running rotating speed
(r/min)
BIT1: Preset rotating speed
(r/min, flashing)
BIT2: Running line speed(m/s)
BIT3: Preset line speed (m/s,
flashing)
Hundreds place of LED:
BIT0: Output power
BIT1: Output toque (%)
Note: The default display shall be
output frequency when all the
parameters are 0
1 007H × √ ○
P16.01
LED display
parameter
selection
2 when
running
Running
display 2
Binary setting:
0: No display; 1: Display
Unit place of LED:
BIT0: Output voltage (V)
BIT1: AI1(V)
BIT2: AI2(V)
BIT3: AI3(V)
Tens place of LED:
BIT0: Analog closed loop
feedback (%)
BIT1: Analog closed loop
reference (%, flashing)
BIT2: Terminal status (without
unit)
BIT3: DC bus voltage
1 00 × √ ○
P16.02
LED display
parameter
selection wh
en stop
Stop display
Binary setting:
0: No display; 1: Display
Unit place of LED:
BIT0: Preset frequency (Hz)
BIT1: Running speed (r/min)
BIT2: Preset speed (r/min)
1 009H × √ ○