EasyManua.ls Logo

Megmeet MV600 Series - Page 116

Default Icon
273 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
116
running with constant speed
(Er.oU3)
7: Reserved
8: Input side phase loss (Er.IrF)
9: Output side phase loss (Er.odF)
10: Power module protection
(Er.drv)
11: Inverter bridge
over-temperature (Er.oH1)
12: Rectifier bridge
over-temperature (Er.oH2)
13: Drive overload (Er.oL1)
14: Motor overload (Er.oL2)
15: External faultEr.EFT
16: EEPROM read-write error
(Er.EEP)
17: Abnormal serial port
communication (Er.SC1)
18: Abnormal contactor (Er.rLy1)
19: Abnormal current detection
circuit (Er.CUr), Hall or amplifying
circuit
20: System interference (Er.CPU)
21: PID feedback lost (Er.FbL)
22: External reference command
lost (Er. EGL)
23: Keyboard parameter copy
error (Er.CoP)
24: Poor auto-tuning (Er.TUn)
25: Local PG fault (Er.PG1)
26: Reserved
27: Reserved
28: Parameter setting error
(Er.PST)
29: Control board 24V power
short circuit (Er.24v)
30: Reserved
31: Expansion card fault (Er.oPT)
32: Reserved
33: Grounding short circuit
(Er.GdF)
34: Large DEV deviation fault
(Er.dEv)
35: Reserved
36: Reserved
37: Reserved (Expansion PG fault
(Er.PG2))
38: PID feedback exceeding limit

Table of Contents

Related product manuals