This function code defines the maximum output frequency when the terminal Y1 is used as the DO
high-speed pulse output terminal.
This function code defines three different central point modes when the terminal Y1 is used as the DO
high-speed pulse output terminal.
0: No central point. As shown in Fig.6-42.
Fig. 6-42 No central point mode
The values corresponding to the pulse output frequency are all positive.
1: Central point mode 1. As shown in Fig.6-43.
Fig. 6-43 Central point mode 1
The pulse output has a central point. The frequency at the central point is half of the maximum pulse
output frequency P09.30. When the output pulse frequency is lower than the central point frequency, the
corresponding values are positive.
2: Central point mode 2
The pulse output has a central point. The frequency at the central point is half of the maximum pulse
output frequency P09.30. When the output pulse frequency is higher than the central point frequency, the
corresponding values are positive.
Pulse output central point selection 0~2 (0)P09.31