204
Fig. 6-67 Retention mode of PLC after single cycle
2: Continuous cycle
As shown in Fig. 6-68, the drive will start next cycle automatically after completing one cycle, and it will
not stop until a stopping command is given.
a
1
f
1
f
2
f
15
f
14
f
1
f
2
f
3
f
3
f
14
f
15
The first cycle
f
1
RUN
command
The second cycle
Fig. 6-68 PLC continuous cycle mode
Tens place: The restart mode selection for interrupted PLC running
0: Restart from the first section
If it is stopped (caused by stopping command, fault or power down) during operation, it will operate from
the first section after restarting.
1: Continue to run from the stage frequency of the stop (fault) moment
If it is stopped (caused by a stopping command or fault) during operation, the drive will automatically
record the running time of the current stage and enter this stage after restarting, and it will complete the
remaining running time at the set frequency of this stage, as shown in Fig. 6-69: