38
Fig. 3-18 The drain connecting mode when using the external power supply
Wiring for Multi-functional output terminals
1. When the Multi-functional output terminals Y1 and Y2 use the internal 24V power supply of the drive,
the wiring mode is as shown in Fig.3-19.
Warning: The inductive load (such as relay) shall be anti-parallel with the fly-wheel diode!
Fig. 3-19 Wiring mode 1 of Multi-functional output terminal
2. When the multi-functional output terminals Y1 and Y2 use the external power supply, the wiring mode is as
shown in Fig.3-20.
Warning: The inductive load (such as relay) shall be anti-parallel with the fly-wheel diode!