PISTON ADHESIVE MELTERMELTER OPERATION
4-21
Automatic pumping block’ enabled
When this function is enabled, whenever an event forces the unit to change
to ERROR mode, STANDBY mode or OFF mode, the pumping block is
automatically enabled, and the STOP button’s red LED lights up.
If conditions allow the unit to return to READY mode, the block can be disabled
by pressing the STOP button. The red LED turns off, and the unit stays in
READY mode.
Example: The unit is in RUNNING mode. At this moment, the
temperature is not OK, and after the programmed time has passed,
the unit changes to ERROR mode. The pumping block is automatically
enabled, and the red LED lights up. The pumping block cannot be
disabled while the temperature is not OK, and the error continues to
be displayed. When the temperature is OK again, the unit does not
automatically change to READY mode. You must press STOP to disable
the pumping block and prepare the unit for pumping.
Automatic pumping block function
The unit has a function for to automatically block pumping due to a voltage
drop, a direct disconnection from the network, or an operating error.
This function can be activated or disabled via the “2. Extra settings / 2.2 Extra
settings” screen.
MICRON+ PISTÓN
HMI : S02001101 v1.1.2
TC : S02200100 v1.0.84
IO FM : XXXXXXXXX vx.x.x
10 min
85 °C 60 s
Modbus
B: 57600Node: 10
2.2 Extra Settings
Inside device temperature alarm
Off after reset
Screen saver
Sound on alarm
Pumping autolock
MICRON+ PISTÓN
HMI : S02001101 v1.1.2
TC : S02200100 v1.0.84
IO FM : XXXXXXXXX vx.x.x
2. Extra Settings
2.2 Extra
Settings
2.3 Input / Output 2.4 Restore default
2.1 Password
MICRON+ PISTÓN
HMI : S02001101 v1.1.2
TC : S02200100 v1.0.84
IO FM : XXXXXXXXX vx.x.x
10 min
85 °C 60 s
Modbus
B: 57600Node: 10
2.2 Extra Settings
Inside device temperature alarm
Off after reset
Screen saver
Sound on alarm
Pumping autolock
Press to
activate
pumping
STOPPED
MODE
READY
MODE
Press to
deactivate
pumping