MA-5162-ENG MICRON
+
PISTON ADHESIVE MELTERMAINTENANCE
5-7
Safety Thermostat
If there is an error in the resettable thermostat. Dismantle the tank casing
with the cover and slide the electrical cabinet along. When you can see the
thermostat, press the button indicated to reset it.
Warning: Use appropriate protective equipment for high temperatures.
Remove the equipment from its base
For more thorough equipment maintenance, it is necessary to remove it from
its present location to be able to perform operations more comfortably and
with greater accessibility.
To do this, the equipment should be removed from its base following these
indications:
1. Turn off the machine switch on the door of the electrical cabinet next to
the pressure regulator.
2. Depressurise the system.
3. Disconnect the hoses connected to the distributor outputs both
electrically and hydraulically.
4. Disconnect the input power supply and ground connection.
5. Raise the machine to extract it from the base.