MC³ 24.96.EX O&M Manual Page 52 08/14/01 4:34 PM/LDD
After entering the values press button.
The difference in percentage will be displayed.
If OK press to accept changes.
Chain Procedure
A chain that produces a known load is placed on the feeder. The controller will record
load readings for a certain amount of belt revolutions. The number of belt revolutions is
determined by the parameter # Proc Revs” (page 28). After the correct number of belt
revolutions is reached, the controller will display a difference between the measured load and the
chain load stored in the controller. A new lads scale factor will be calculated. You will then have
the option of accepting or rejecting the new value.
NOTE: After running a Chain Factor Procedure, the Factored Chain value is used.
To begin the Chain Procedure press the button. The display will show:
If your chain has been installed and you are ready to begin the Chain Procedure press the
button. The display will show the percentage of test completed:
After the test is complete the display will show: