Grouping of Parameter Settings
In order to facilitate the entry of the parameters that can be set, they have been divided into four groups as shown below:
•
Group “0” = settings for technical functions
•
Group “1” = settings for the regeneration Cycle 1
•
Group “2” = settings for the regeneration Cycle 2
•
Group “3” = settings for the regeneration Cycle 3
•
Group “4” = settings for the maintaining Cycle
•
Group “9”= section for the serial number of the machine (please note this can only be accessed and seen when
reprogramming a new Eprom or when reprogramming After LO.
Logical Entry Sequence For Entering Parameters In Each Group
The various parameters to be entered for each group are numbered and follow the logical sequence shown below:
• Group “1” parameter “1” oven temperature setting.
• Group “1” parameter “2” total cycle time in minutes.
• Group “1” parameter “3” oven ventilation temperature setting.
• Group “1” parameter “4” duration in minutes of the ventilation cycle.
• For groups 2,3 and 4, repeat group 1 sequence.