External Food Probe
Detachable external food probe
The detachable external food probe is connected to the trolley by plugging it in to the external blue probe socket, which is
located on the front panel next to the touch pads. The probe is used to check the temperature of food products prior to and
after regeneration. The temperature read out of the probe will only be displayed when none of the regeneration cycles are
selected, an audible bleep indicates that the temperature reading is below 10°C (50°F) or above 75ºC (167°F).
Detachable external food probe – HIT
The detachable HIT external food probe is connected to the trolley by plugging it in to the external blue probe socket, which is
located on the front panel next to the touch pads. The probe is used to check and record the temperature of food products prior
to and after regeneration. The temperature of the food product time and date is recorded by pressing the switch and then
immediately releasing it. An audible bleep follows two seconds later to confirm that the data has been recorded. The
temperature read out of the probe will only be displayed when none of the regeneration cycles are selected, a continuous
audible bleep indicates that the temperature reading is below 10°C (50°F) or above 75ºC (167°F).
Do not hold the switch down for more than half a second or the display will revert to its normal mode.
If the temperature exceeds 110°C (230°F) the display will no longer show the reading from the probe and will revert back to
the normal display mode.
Correct Use
• Ensure that the oven is not in cycle.
• Connect the food probe to the external blue socket on the trolley.
• Remove from one product at a time from the oven or cold side and close the door.
• Place the product on the top plate above the oven section
• Clean the probe with an antiseptic wipe
• Insert the probe into the centre of the food product.
• The product temperature will be displayed accompanied by an audible bleep if the product temperature is below 10°C
(50°F). Or above 75°C (167°F).
• Press and release the switch immediately releasing it.
• An audible bleep follows two seconds later to confirm that the data has been recorded.
• Return the food product to its original compartment and close the door.
• Clean the probe with an antiseptic wipe. A new wipe should be used for each item tested.
• Repeat the above procedure for further temperature testing of food products.
• Make sure the probe has been cleaned before storing.
:
• Do not place the probe or measure temperatures in side either the oven or cold chambers.
• Do not attempt to probe frozen products.
• Do not hold the switch down for more than half a second.
• Do not over stretch the cable.
• Do use for any other purpose than food temperature testing.
;
• Do use with care
• Do keep the probe clean
• Ensure that the probe is stored safely
This probe is a accurate measuring instrument and must be treated with great care.
Two clips on the front panel are provided to hold the probe while the trolley is in use. The sharp tip of the probe can
represent a hazard if misused. Remove the probe from the trolley at the end of every meal service and store it away
safely. The tip of the probe must be cleaned thoroughly using a sterile wipe before and after every use.
This feature must only be used with a Burlodge probe.