26.
Special Features
Memorised Power Supply Failure
Various start-up procedures and oven cycle settings are kept in memory. In the case of a power failure (or if the “OFF” touch
pad is pressed), the cycle will restart if you press the “ON” touch pad. The cycle will continue from where it was interrupted.
During the interrupted cycle or power failure, if the temperature of the oven goes below 70ºC (158ºF) the oven cycle time is
reset and a new cycle will need to be started.
Audible Warning
Quick intermittent beeps denote the alarm status.
A slow intermittent beep denotes normal status i.e. end of a cycle.
A slow intermittent beep denotes if the optional external food probe registers a temperature below 10ºC (+50°F) or above
75ºC (167°F).
Memory Back Up
The default settings remain in the memory even if the microprocessor batteries are discharged. Refer to the Programming Data
Table that summarises both the permissible ranges of the values that can be modified and the pre-set default values. The
battery has an expected life of eight years and it is recommended that it be replaced after seven years. Contact the Burlodge
Technical Department.
Maintaining Cycle
This function allows the oven to be used to maintain the temperature of the product in the oven section after regeneration or
boosting in conjunction with the display light (the light is always automatically switched off if any of the other oven cycles are
selected). This cycle can only be selected by pressing and holding oven cycle 3 for 5 seconds. Please note the if the light has
already been selected it will be initially switched off when the cycle is selected then come back on after 5 seconds.
The temperature and time of maintaining cycle could be setted with parameters 41 and 42.
NB: To enable the boosting when CO is enabled use this sequence:
In sequence press cycle touch pad 3, ( CO ) will appear : press cycle 2, then 1 then 3, and keep depressed cycle 3 until
maintaining cycle starts.
Battery Display System
This option allows the control panel to be switched on for a period of 20 seconds without the unit being connected to a power
source. All the displays will function normally and permit the use of the external food probe for temperature product testing.
The control panel will automatically be switched off after 20 seconds. This function can be repeated as many times as
required.
Split Heated Top Plate and Gantry
The Heated Top Plate can either be used with all the top plate heated or split use with one half heated for service of hot foods
and the other half un-heated for the service of cold foods. Press the pad once for all of the top plate and the entire overhead
gantry heating, the LED will remain on permanently. Press the pad for a second time and only half of the top plate and gantry
will heat up (this will always be the section above the oven). The LED will continuously flash on and off to confirm this
status.
Touch Pad Lock (CO)
It restricts the use of the trolley to authorized personnel; the trolley can be programmed so that the cycle will not start until the
starting code has been entered. The starting code is requested by the message “CO” which will appear in display 1 after a cycle
touch pad has been pressed. To start a cycle: select the required cycle, press cycle touch pad 2 then 1 then 3 in quick
succession. The refrigeration system will work as normal and will not be affected by this function.