40.
Towing Procedure For The Multigen Dollies
!
Coupling
Check that the locking pin has secured the transfer module to the dolly and fit the cover over the module.
Release the brakes on the castors.
Align the front of the dolly to the rear of the towing hitch.
Raise the towing arm side ways to the upright position then pull the arm forward until it is slightly below the
horizontal position and locate the tow arm ring on to the towing pin of the towing hitch.
Never tow more than four Dollies at a time
If towing more than one Dolly align the front of the second Dolly and follow the above procedure.
Un-coupling
If there is more than one dolly always commence from the last dolly being towed.
Ensure the floor is flat and even.
Press down the towing arm and release it from the towing pin, raise the arm to the upright position then lower
the arm side ways to its storage position.
Caution! The towing arm is spring loaded, so take additional care when carrying out this procedure.
Apply the brakes before leaving the Dolly.
Repeat the above operation until there is only one dolly left. Uncouple this last dolly from the towing hitch (this
part of the operation may vary slightly depending on the towing attachment fitted to the towing hitch).