12.09.05 rev 1.0
20
21. Programming the Automatic Timer Settings continued
Programming Cycle Options for Auto Start Timer
CYCLE OPTIONS for Auto Start Timer CODE
No cycle start 00
Cycle 1 01
Cycle 2 02
Cycle 3 03
HOSTESS OPTIONS CODE
No options 00
Cold light only 01
Cold light plus all of the heated top plate and gantry 02
Cold light plus the left-hand half of the heated top plate and gantry 03
Cold light and refrigeration 04
Cold light and refrigeration **** and all of heated top plate and gantry 05
Cold light and plate warmer **** and all of heated top plate and gantry 05
Cold light and refrigeration ***** and the left-half of the of heated top plate and gantry 06
Cold light and plate warmer ****and the left-half of the of heated top plate and gantry 06
Cold light and refrigeration 04
The cold light option will switch on at the end of the cycle
The refrigeration, plate warmer and top plate options will switch on 45 minutes prior to the cycle start time. The cold light
option will switch on at the end of the cycle.
**** D4 + M1 software for Multigen with the plate warmer option
***** D5 + M2 software for Multigen with the refrigeration option
Press the Off pad
The trolley is now programmed to your requirements and ready to be used