A new inspection was started from the
Single test main menu
Saving under the last selected Structure
object will be offered by default. The user
can select another Structure object or create
a new Structure object. By pressing the Save
key in Memory organizer menu the
inspection is saved under selected location.
An empty inspection was selected in
Memory Organizer and started
The result(s) will be added to the inspection.
The inspection will change its status from
An already carried out inspection was
selected from Memory Organizer,
viewed and then restarted
A new inspection will be saved under the
selected Structure object.
6.3.4 Help screens
Help screens contain diagrams for proper connection of the instrument.
6.4
Environmental data are measured with the A 1785 PV Remote WL with sensors mounted
on the PV modules. The instrument is usually in another location (at the inverter, combiner
box). For getting STC results, the environmental data from the PV remote WL and
measurements on the instrument must be combined. Date & time synchronization between
the instrument and A 1785 - PV Remote WL is automatic, during Wi-Fi connection and when
the instrument is switched on. For this purpose, the instrument and the PV Remote WL shall
be wirelessly connected.