Installation, Programming and Maintenance Microdos Pooltec
Rev. 1.0 EN
20
There are five possible operating programs for the recirculation pump.
NOTE: if you need help while configuring the various programs, please consult the help menu on your device.
PROGRAMS
4.5.2.1. AUTOTEMP:
Operation will depend on the water temperature:
the number of hours of operation of the recirculation pump is half of °C (for example if the temperature detected is 26°C the pump
will be on for 13 hours).
NOTE:
1. To activate the program:
- With a short press on the day, you access in the settings for the selected day.
- With a second short press on the day, the program is activated on that day (blue colour).
- If you wish to use the daily program already set, copy it for the entire week by pressing SET ALL WEEK.
2. Weekdays colour:
a. BLUE: the program is active on the day.
b. GREY: the program is not active on the day.
3. Always press SAVE to make the modification effective.
4. Pump On “00:00” → no programming
BASIC MENU:
Operation will depend on the water temperature.
The system measures the water temperature after 2 minutes from the filtration beginning and
automatically calculates the operating time of the pump. These times are recalculated every 30 minutes
based on the water temperature.
The user can program up to 3 daily timers for the activation of the recirculation pump.
The recirculation pump is factory set for 24 hours a day.
The user can program up to 3 daily timers for the activation of the recirculation pump.
It is possible to set a water frost protection.
There is no program for the activation of the recirculation pump.
Heating cannot work.
For this program you need to enter:
-
start time of the recirculation pump
for the selected day.