Installation, Programming and Maintenance Microdos Pooltec
Rev. 1.0 EN
50
HEAT PUMP:
mA OUTPUTS:
TEMPERATURE:
6.2. RECOMMENDED TIME SCHEDULE FOR PRIVATE/PUBLIC POOLS
For the Pooltec system to be efficient, we need to remember that the hours of daily operation depend directly on the water
temperature. The higher the temperature, the greater the number of hours of operation required.
For this, we recommend:
Private pools: we recommend the AUTO-TEMP program.
Public pools: we recommend the PUBLIC POOL program (24 hours continuously)
7. MAINTENANCE OF THE MICRODOS POOLTEC
7.1. MAINTENANCE AND CONTROL PANEL
From now on, the only thing we need to do is to maintain the system, checking the parameters detailed below:
GENERAL MAINTENANCE
- Replenish/ replace the tanks for products used. You must never allow these to get low.
- Change the measurement probes for pH and Rx as soon as the calibration frequency increases, or they fail to calibrate
(Approximately 2 years under normal conditions of use). Never allow a probe to have no water.
- It is strongly necessary to delete samples of measurements at least every 6 months (DEVICEHISTORY
MEASUREMENTSDELETE SAMPLES)
DAILY MAINTENANCE
- Ensure that the pump is working, and that no alarms have been triggered (visually in orange).
- Ensure that the water is clean and clear (visually).
MONTHLY MAINTENANCE
- Check the pH in the vessel at least once a month (using colour-graded or digital gauges).
BI-MONTHLY MAINTENANCE
- Calibrate the pH and Rx probes, or whenever the vessel measurement does not agree with what is indicated on the control unit
by ± 0.2 pH.
- Check the silicon injection pipe, product pipes and injectors of the dosing pump(s).
HEAT PUMP
OFF
MIN TEMPERATURE
26°C
MAX TEMPERATURE
28°C
OUTPUT
mA1
mA2
MODEL CONFIGURATION
pH
pH-RX
pH-CL
pH-RX-CL
BASIC
MEASURE
PH
RX
CL
CL
4mA
7.20PH
730mV
1.30ppm
1.30ppm
20mA
8.20PH
630mV
0.30ppm
0.30ppm
EXPERT
AL.mA
0.00mA
0.00mA
0.00mA
0.00mA
OVERDOSE
00:00
00:00
00:00
00:00
OVERDOSE LIMITS
00:00
00:00
00:00
00:00
°C/°F
°C