Installation, Programming and Maintenance Microdos Pooltec
Rev. 1.0 EN
23
4.5.2.4. WINTER
NOTE: Only the recirculation pump works.
Configure up to 3 daily timers to program the activation of the recirculation pump.
1. To activate the program:
- With a short press on the day, you access in the settings for the selected day.
- With a second short press on the day, the program is activated on that day (blue colour)..
- If you wish to use the daily program already set, copy it for the entire week by pressing SET ALL WEEK.
2. Weekdays colour:
a. BLUE: the program is active on the day.
b. GREY: the program is not active on the day.
3. Always press SAVE to make the modification effective.
4. Values of On at “00:00” and Off at “00:00” no programming on recirculation pump
FROST PROTECTION:
Set the minimum and maximum water temperature for the frost protection function.
The pump is activated during no-working periods, every hour for 10 minutes and the water temperature is monitored.
If the temperature is below the ON under value, the pump continues to work until it reaches the OFF over temperature.
FROST
PROTECTION