1. IMPORTANT SAFETY INSTRUCTIONS
1.1. ELECTRICAL SPECIFICATIONS AND FEATURES
ELECTRICAL SPECIFICATIONS:
Power supply 110÷230 VAC
Operating frequency 50 Hz
Energy consumption when not running 120 mA.
Operating temperature + 5° / + 55°C
Maximum operating humidity 95% with no condensation
Protection of the environment IP55
OPERATING ALGORITHMS:
Manual/ automatic operation? Yes
User programs? Yes
Temperature display At 0°/55°C intervals; accurate to +/- 0.1ºC
pH display At 0/14 pH intervals
ORP display At intervals of 0/1000 mV.
Automatic pH dose corrector By peristaltic/solenoid pump
Automatic Rx dosing By peristaltic/solenoid pump
Touch-screen Colour 10"
Programming By touchscreen and passwords (expert and installer)
Type of programming User-friendly and intuitive
WARNINGS FOR GENERAL OPERATION OF MICRODOS POOLTEC
1. VERIFY PROGRAMMING AFTER UPTDATING THE DEVICE: TIME PROGRAMMING, PH AND RX SET POINTS, HEATING, ETC...
2. ACCESS CODE – For menus and special functions:
The installer password can be changed (see page 40)
ATTENTION: the device is designed to stay on 24 hours a day, avoiding frequent shutdown cycles.
PLEASE READ AND FOLLOW THESE INSTRUCTIONS
It is essential when installing a control and disinfection system at a pool to take certain precautions
while handling equipment, also more generally when using the pool.
DANGER: Low-voltage electricity risk: Do not open or touch the control unit: there is a risk of electric shock.
Contact your local retailer or the manufacturer.
Follow the electricity safety instructions specified by your company, also local or national regulations.
DANGER: Risk of accidents or drowning: Use of the pool calls for special care. Observe the safety and
hygiene instructions laid down. These are displayed near the pool, or in accordance with local or national
regulations.