16
MicroEn
ine
XP-GT/GTR Programming Manual
v4.00
List of programmable parameters include:
i. Lock Release Time
Description
: Duration for the lock to be released every time a valid
access is granted.
Value
: 00 - 99 seconds.
Default value : 10 seconds.
ii. Door Open Time
Description
: Duration for the door to be opened before being
considered as ‘Door Left Open’.
Value
: 00 - 99 seconds.
Default value
: 15 seconds.
iii. Lock Release Time Zone
Description
: Time Zone setting for Automatic Lock Release. This
will determine the day of the week and the time of the
day to automatically release the door lock for free
access.
Value
: 00 – 50.
Default value
: 00. (No free access)
iv. Exit Button Time Zone
Description
: Time Zone setting for Exit Button. This will determine
the day of the week and the time of the day where
the exit push button will be enabled.
Value
: 00 – 50.
Default value
: 01. (Exit button enabled at all times)
v. Auto Pin Mode
Description
: AutoPin Mode enabled or disabled. Once enabled,
users can gain access only by entering a pre-
programmed pin number.
Value
: ON, OFF.
Default value
: OFF.
NOTE:- Sub-menu v. is only available to GT/GTR (1200, 3000, 3200, 1200L,
3000L, 3200L) series only.
vi. Security Off
Description
: Security Off Mode enabled or disabled. Once enabled,
the door lock will be permanently released until this
parameter is disabled.
Value
: NO, YES.
Default value
: NO.