vii. Anti PassBack
Description
: Anti PassBack Mode enabled or disabled. Once
enabled, users are prevented from using the same
card to gain access through the same direction
successively without first gaining access from the
opposite direction.
Value
: ON, OFF.
Default value : OFF.
viii. Card Lock Out
Description
: Card LockOut Mode enabled or disabled. Once
enabled, users will be locked out permanently after
failing to gain access for three consecutive times.
The failure might be caused by wrong pin number,
wrong time zone or anti passback violations.
Value
: ON, OFF.
Default value
: OFF.
ix. Tamper
Description
: Tamper Mode enabled or disabled. Once enabled,
controller will sound buzzer when the cover is pried
open.
Value
: ON, OFF.
Default value
: OFF.
x. Hi Security Mode
Description
: High Security mode selection. Users
can choose one of the 3 modes for additional
security. Hi Security Mode is activated by setting
the Hi Security Time Zone in the next menu.
Value
: Token+Pin(00), Token+Fingerprint(01),
Token+Pin+Fingerprint(02).
Default value : 00
xi. Hi Security Time Zone
Description
: Time Zone setting for Hi Security Mode. This will
determine the day of the week and the time of the day
where Hi Security Mode will be enabled.
Value
: 00-50
Default value
: 00 (Hi Security disabled)
xii. Int Rdr Enable
Description
: Internal Reader enabled or disabled. Once enabled,
controller’s built-in reader will be enabled to read card
for door access application.
Value
: YES, NO.
Default value : YES.
NOTE:- Sub-menu xii. is only available to GT/GTR (1500L, 3500L, 1500ABL,
3500ABL) series only.