Technical Information
22
T 80xx
1 Technical Data
Drum design
Honeycomb design
Maximum load
T 80xx, T 80xx C: 13.2 lbs (6 kg)
T 8019 CI: 11 lbs (5 kg)
Drum volume
T 80xx, T 80xx C: 28 gal (105L)
T 8019 CI: 26 gal (100L)
Drum light (H3/6)
E 14 bayonet closure, activation via relay on the
electronic (EPWL). USA: 120V, 15W, 572°F (300°C)
Heater bank
Duct heater bank (R1, R2); 2-filament
Heater output
USA/CAN: 120/208-240 V, 60Hz: 2.6kW (1.44kW +
1.16kW)
MEX: 127/220V, 60Hz: 2.6kW (1.44kW + 1.16kW)
Temperature sensor
Heater bank NTC (2R30), position at heater bank (R1,
R2), drum perforation temperature
Temperature limiter
Temperature limiter (F2, SOD), position at heater bank
(R1, R2) - air entrance to drum, 347°F (175°C) ± 8
degrees
Vented dryer: ¾” (1.9 cm); condenser dryer: ½” (1.3 cm)
Table 030-1: Technical Data
Temperature Resistance (kΩ)
°F °C Heater bank NTC (2R30) Drying-air NTC (1R30)
32 0 340 38.0
41 5 261 29.7
50 10 203 23.4
59 15 159 18.6
68 20 126 14.9
77 25 100 12.0
86 30 80.2 9.73
95 35 64.8 7.96
104 40 52.7 6.55
113 45 43.1 5.42
122 50 35.5 4.52
131 55 29.4 3.78
140 60 24.5 3.19
149 65 20.5 2.70
158 70 17.3 2.29
167 75 14.6 1.96
176 80 12.5 1.68
185 85 10.6 1.45
194 90 9.13 1.25
199 93 8.34 1.15
203 95 7.86 1.09
212 100 6.80 1.06
230 110 5.14 0.73
248 120 3.95 0.569