EasyManua.ls Logo

Miele T 80 Series - Rear Service Panel Access; Condensate Pump Removal

Miele T 80 Series
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Information
42
T 80xx
1 Technical Data
Condensate pump (M5) Approximate power rating 25W
Pressure hose length 4.9' (1.5m)
Maximum head height 4.9' (1.5m)
Maximum head height with non-return valve 3.3' (1m)
Maximum drain length 13' (4m)
Control Time- and level-controlled
Table 070-1: Technical Data
4 Service
4.1 Rear Service Panel Removal
1. Remove the T30 screw securing the plastic rear service panel (Figure
070-1, Item 1).
2. Take off the rear service panel; remove the hose from the panel.
Figure 070-1: Rear Service Panel
4.2 Condensate Pump Removal
Note:
Have cloths or rags handy!
1. Disconnect the appliance from the power supply.
2. Remove the rear service panel; see Section 070-4.1.
3. Take off the metal clamp.
4. Lift the pump up and out of the condensate box.

Table of Contents