Technical Information
42
T 80xx
1 Technical Data
Condensate pump (M5) Approximate power rating 25W
Pressure hose length 4.9' (1.5m)
Maximum head height 4.9' (1.5m)
Maximum head height with non-return valve 3.3' (1m)
Maximum drain length 13' (4m)
Control Time- and level-controlled
Table 070-1: Technical Data
4 Service
4.1 Rear Service Panel Removal
1. Remove the T30 screw securing the plastic rear service panel (Figure
070-1, Item 1).
2. Take off the rear service panel; remove the hose from the panel.
Figure 070-1: Rear Service Panel
4.2 Condensate Pump Removal
Note:
Have cloths or rags handy!
1. Disconnect the appliance from the power supply.
2. Remove the rear service panel; see Section 070-4.1.
3. Take off the metal clamp.
4. Lift the pump up and out of the condensate box.