Technical Information
21
T 980x/T 982x
1 Technical Data
Maximum load
17.6 lbs (8 kg)
Drum volume
48 gal (180L)
Drum speed
48 rpm
Table 030-1: Drum Data
Heating mode
Electric; for gas, refer to Table 031-1.
Heater type
Duct heater bank (R1, R2, R3); 3-filament
Heater output
5.2kW (1.90kW, 1.70kW, 1.60kW)
Temperature sensor
Heater bank NTC (2R30)
Temperature limiter
3 x 3/4“ temperature limiter (F1) with manual reset, 16A
Drum light (H3/6)
E 14 bayonet closure, activation via relay on the
electronic (EPWL). USA: 120V, 15W
Table 030-2: Heater Data
Temperature Resistance (kΩ)
°F °C
Heater bank NTC
(2R30)
Drying air NTC
(1R30)
32 0 340 38.0
41 5 261 29.7
50 10 203 23.4
59 15 159 18.6
68 20 126 14.9
77 25 100 12.0
86 30 80.2 9.73
95 35 64.8 7.96
104 40 52.7 6.55
113 45 43.1 5.42
122 50 35.5 4.52
131 55 29.4 3.78
140 60 24.5 3.19
149 65 20.5 2.70
158 70 17.3 2.29
167 75 14.6 1.96
176 80 12.5 1.68
185 85 10.6 1.45
194 90 9.13 1.25
199 93 8.34 1.15
203 95 7.86 1.09