EasyManua.ls Logo

Miele T 980x - F4: Drying Air NTC (1 R30) Open Circuit; F50: Motor Stalls and Heater Is on for 3 Seconds; F55: Overriding Time Limit Exceeded

Miele T 980x
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Information
57
T 980x/T 982x
3.11 F4: Drying Air NTC (1R30) Open Circuit
Symptom:
Program stop, cooling phase, intermittent buzzer tone.
Only the timed program “cold air” still works.
The “Hand iron” LED flashes.
The “Check Filter/Vent” LED flashes.
Opening and closing the door deletes this fault indication.
Cause:
Open circuit (below 5°F) in the drying air NTC (1R30).
Remedy:
Check the wires and connectors of drying air NTC 1R30 for a short or open circuit.
For drying air NTC resistance values, refer to Table 030-3.
3.12 F50: Motor Stalls and Heater Is On for 3 Seconds
Symptom:
The motor (M5) stalls.
Program stop, cooling phase, intermittent buzzer tone.
Opening and closing the door deletes this fault indication.
Cause:
This is an internal electronic fault.
Remedy:
1. Check the motor.
2. Replace the electronic.
3.13 F55: Overriding Time Limit Exceeded
Symptom:
Only in residual moisture programs.
Program stop, cooling phase, intermittent buzzer tone for 2 minutes.
The “End” LED lights up steadily.
The “Check Filter/Vent” LED lights up steadily.
Opening and closing the door deletes this fault indication.
The safety time has been exceeded; refer to Section 090-2.6.
Cause:
Laundry too wet, or dryer overloaded.
Remedy:
Spin the laundry more thoroughly in the washer, or reduce the laundry load.
Cause:
Laundry is electrically conductive (low-ohmic), due to a metal zipper, for example.
Remedy:
Run a timed warm-air program.
Cause:
Air path clogged.
Remedy:
Check and clean the air paths.

Table of Contents