EasyManua.ls Logo

Miele T 980x - Felt Seal Replacement; Figure 050-3: Felt Seal Installation

Miele T 980x
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Information
47
T 980x/T 982x
4.2 Felt Seal Replacement
1. Disconnect the machine from the power supply.
2. Remove the air shield (Section 050-4.1) but do not disconnect any electrical
connections.
3. Lean the air shield against the appliance with the felt seal exposed.
4. Prop up the front of the drum to reduce any strain on the rear bearing.
5. Remove the felt seal by gently prying up the three staples.
6. Clean the drum where the new seal will make contact.
7. Install the new felt seal with the seam facing straight down (6 o'clock position).
See Figure 050-3.
8. Staple the felt seal at the 12, 4 and 8 o'clock positions. See Figure 050-3, Item 1.
Note:
When stapling the felt seal, note the following:
Ensure that the stapler is set to maximum tension for proper penetration.
Ensure that the felt is lifted back without shifting the rubber base.
Ensure that the stapler is held firmly against the felt seal rubber base and
the air shield.
Ensure that the staple penetrates the air shield.
Figure 050-3: Felt Seal Installation
9. Inspect the fan impeller for dirt, debris or damage. Replace if necessary
(see Section 040-4.1).
10. Reinstall the air shield, following the instructions in Section 050-4.1 in

Table of Contents

Related product manuals