3 Fault Repair
3.1 “End” LED Is Steadily Lit
Symptom:
This fault occurs in the normal operating mode (residual moisture programs only).
Program stop, cooling air phase, intermittent buzzer tone.
Opening and then closing the door deletes this fault message.
Cause:
The drum is empty, or loaded with only a few laundry items.
The laundry is too dry.
The residual moisture sensor (B3/1) voltage circuit is high-ohmic, and the residual
moisture sensor has no-load detection; this is not a technical fault.
For no-load detection, refer to Section 030-2.1.
Remedy:
Adjust the load, or switch to a timed program.
Cause:
Defective residual moisture sensor (B3/1).
Remedy:
Check the residual moisture sensor (B3/1) for low-ohmic (continuity) status; refer to
Section 090-4.3.
3.2 “Check Filter/Vent” LED Is Steadily Lit
Symptom:
Normal program run.
Fault indication at the end of the cooling cycle.
Insufficient air detection; refer to Section 090-2.7.
Opening and closing the door deletes this fault code indication.
Cause:
Air paths are clogged.
Remedy:
Clean the lint filter (refer to the operating instructions).
Clean the air paths in the dryer.
Cause:
The fault message Clean air paths is issued prematurely.
Remedy:
Reprogram the Clean air paths fault message indication; see the operating
instructions or Section 090-4.1.