EasyManua.ls Logo

Miele T 980x - Table 090-4: Programming Mode Summary

Miele T 980x
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Information
61
T 980x/T 982x
Programming Function Option
“Buzzer” LED long short “Drying” LED short
Reset, refer to Section
090-2.4.1
-- 1
adapted options 0
delivery
condition
1
Normal drying
outcome (residual
moisture), refer to
Section 090-2.4.2
-- 2
more damp 0
standard
1
more dry 2
Delicates drying
outcome (residual
moisture), refer to
Section 090-2.4.3
-- 3
more damp 0
standard
1
more dry 2
Memory, refer to
Section 090-2.4.4
-- 6
off, memory
function not
activated
0
on, memory
function
activated
1
Additional cooldown
phase, refer to
Section 090-2.4.5
-- 7
off
0
5 min 1
10 min 2
Insufficient air alert,
refer to Section 090-
2.4.6
1 --
off 0
more sensitive 1
standard
2
less sensitive 3
Button tones, refer to
Section 090-2.4.7
1 1
off 0
on
1
Conductivity setting,
refer to Section 090-
2.4.8
1 2
normal
0
low (<150µS) 1
Standby, refer to
Section 090.2.4.9
1 3
off 0
on 1
Table 090-4: Programming Mode Summary
Save and quit:
Open the door.
Note: Programming selections are saved in the electronic.