Technical Information
50
T 980x/T 982x
1 Technical Data
Electric Heating Gas Heating
Electronic (1N1)
USA: EPWL 341
(single-board electronic)
USA: EPWL 345
(single-board electronic)
Can be updated via optical PC interface installed
standard
Drying technology
Residual moisture sensing: conductivity test,
residual moisture sensor (B3/1), 1-rib sampling
Insufficient air detection via heater bank NTC 2R30
and drying air NTC 1R30
Table 090-1: Technical Data
2 Function
2.1 Reversing (Electric) (T 980x)
Reversing rhythm: 5 minutes clockwise (default direction), 1.5-second
pause, 30 seconds running counterclockwise, 1.5-second pause.
During the clockwise run, shortly before the pause, heating is reduced to a
basic output of 1.9kW.
2.2 Reversing (Gas) (T 982x)
During the drying cycle, the gas dryer will not reverse for residual laundry
moisture levels below 20%.
For residual moisture levels greater than 20%, a maximum of 7 reversing
cycles will take place.
Reversing rhythm: 10 minutes running clockwise (default direction), 1.5-
second pause and 30 seconds running counterclockwise.
The burner is switched on at the start of the clockwise run, and it is switched
off 4 seconds before the start of the counterclockwise run. During the
counterclockwise run, the burner is always off.
2.3 Dryer Function after a Power Interruption
The dryer continues automatically at the point the program was interrupted.
2.4 Programming Functions
2.4.1 Resetting to Factory Settings
Resets all programming options to their factory settings.
Note:
The reset takes effect immediately; it's not possible to restore the previous settings!
Operating hours are not reset.
Not possible with service-department electronics.