Technical Information
29
T 980x/T 982x
1 Technical Data
Heating mode
Gas; for electric, refer to Table 030-2.
Gas burner
Gas burner, pipe configuration, 5.7kW. Model: Venturi
Natural-gas version -
output
5.4kW ANSI Gas A, 1076 BTU/ft
3
Temperature sensor
Heater bank NTC (2R30)
Temperature limiter
Two 3/4” bi-metal temperature limiters (1F1, 2F1) with
manual reset, 16A, 248°F/212°F ± 5 K
Safety time; refer to
Section 031-2.1.3
90 seconds
Table 031-1: Gas Heating Data
2 Function
2.1 Gas Unit
2.1.1 Gas Solenoid Valve (Y57)
In gas dryers, gas solenoid valve Y57 is activated via heater relays 1K1/1
and 2K1/1.
Gas solenoid valve Y57 consists of gas solenoid valves Y57/1 and Y57/2.
Gas solenoid valve Y57/1, in turn, consists of a maintaining coil and a
booster coil.
Gas solenoid valve Y57 only opens when both solenoid valves (Y57/1
and Y57/2) are opened.
Gas solenoid valve Y57/1 only opens when its maintaining and booster
coils carry voltage.
Once gas solenoid valve Y57/1 is open, it remains in this state as long as
its maintaining coil carries voltage.