EasyManua.ls Logo

Miller Syncrowave 250 DX - Coolant Maintenance and Oiling Motor

Miller Syncrowave 250 DX
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
OM-363 Page 53
6-5. Coolant Maintenance And Oiling Motor
801 195-A / Ref. 801 194
! Disconnect power
before maintaining.
1 Coolant Filter
Unscrew housing to clean filter.
Changing coolant: Drain coolant by
tipping unit forward. Fill with clean
water and run for 10 minutes. Drain
and refill.
If replacing hoses, use hoses
compatible with ethylene gly-
col, such as Buna-n, Neo-
prene, or Hypalon. NOTE:
Oxy-acetylene hoses are not
compatible with any product
containing ethylene glycol.
1
Low Conductivity Coolant
No. 043 810**;
Distilled Or Deionized Water
OK Above 32° F (0° C)
GTAW Or Where
HF* Is Used
Application
*HF: High Frequency Current
**Coolant 043 810, a 50/50 solution, protect to -37° F (-38°C) and resist algae growth.
Coolant
3-1/2
Gal
NOTICE Use of any coolant other than those listed in the table voids the warranty
on any parts that come in contact with the coolant (pump, radiator, etc.)