PL-565 Accumass BW500 Page 59
Parameters
P005 Design Rate Units
Selects the units of measurement used.
imperial P004 = 1 metric- P004 = 2
1
f
=
T/h(tons / hour) t/h (tonnes / hour)
2 = LT/h(long tons) / hour kg/h (kilograms / hour)
3 = lb/h(pounds / hour) kg/min (kilograms / minute)
entry:
4 = lb/min (pounds / minute)
Changing this parameter does not affect the rate (P011), belt speed (P014) or belt
length (P016) parameters. These parameters should be re-entered for conformity in
units.
t = 1000 kg
LT = 2240 lb.
T = 2000 lb.
P008 Date
Enter the current date in yyyy-mm-dd format.
where:
yyyy = year
mm = month, 01 12
dd = day, 01 31
e.g. 1999-03-19 (March 19, 1999)
P009 Time
Enter the current time in hh-mm-ss 24 hour format.
where:
hh = hour
mm = minute
ss = second
P011 Design Rate
Specifies the design rate of material flow for the belt scale. (f=0.00)
Enter the design rate from the supplied design data sheet, in the units selected (P005).
P014 Design Speed
Specifies the design speed for the conveyor belt. (f=0.00)
Speed units are:
feet/min if the imperial system of measurement has been selected, P004 = 1
metres/s if the metric system of measurement has been selected, P004 = 2