- 3.7 -
Cleaning the nozzle [NOZZLE WASH]
If nozzle clogging cannot be resolved even after cleaning several times,
execute the [FILL UP INK] and [WASH] functions (
page 5.11) .
If this error cannot be resolved with these functions, contact the dealer.
STEP
1. Push the [FUNCTION] key.
2. Push the key until the display gives the indica-
tion [MAINTENANCE].
3. Push the [ENTER] key.
[STATION] is displayed.
4. Push the [ENTER] key.
[NOZZLE WASH] is displayed.
5. Push the [ENTER] key.
Move the carriage on the platen.
6. Open the front cover.
7. Fill the cap with the cleaning fluid using a
dropper.
8. Close the front cover, and push the [ENTER]
key.
9. Press the [
] and [ ] key, select the time to
leave. (1-99 mins: 1 min unit)
Normally set 1 min.
10. Push the [ENTER] key.
The indication at the right display continues during selected
time to leave for sucking the cleaning solution and cleaning.
11. Return to the LOCAL mode.
FUNCTION
SET UP < ENT >
FUNCTION
MAINTENANCE < ENT >
MAINTENANCE
STATION < ent >
STATION
MENT : NOZZLE WASH
STATION
COMPLETED : ent
STATION
TIME : 1 min
INITIALIZING
PLEASE WAIT
< LOCAL >