Color Inkjet Printer JV33-130/160
2-30
XY SERVO MOTOR
Operation test of XY-servo motor is executed.
Note: During the test, heater temperature control is allowed (When HEATER key is effective).
WIPER MOTOR
Operation test of wiper motor is executed.
< XY-servo motor test sequence>
No. Item Content Notice
1 X speed designation [], []: Speed selection
Set value: 1 ~ 150 mm/s (unit: 1 mm/s)
[], []:
Selection of item
2~4
[ENTER]:
Transit to setting
in the Y
direction (5~)
2 X acceleration
designation
[], []: Acceleration selection
Set value: 0.01 ~ 0.50 G (unit: 0.01 G)
3 X moving amount
designation
[], []: Moving amount selection
Set value: 1 mm ~ Paper length (unit: 1 mm)
When media is not detected: 1 mm ~ 500000 mm
press
[ENTER]
to start Y-axis motor setting
4 Y speed designation [], []: Speed selection
Set value: 1 ~ 1500 mm/s (unit: 1 mm/s)
[], []:
Selection of item
5~7
[ENTER]:
Transit to the
following step
[END]: Transit
to setting in the
X direction (2~)
5 Y acceleration
designation
[], []: Acceleration selection
Set value: 0.05 ~ 2.00 G (unit: 0.05 G)
6 Y moving amount
designation
[], []: Moving amount selection
Set value: 1 mm ~ Paper width (unit: 1 mm)
When media is not detected: 1 mm ~ Mechanical limit size
7Cap OFF Only after media
detection
8 Moving
[ENTER]
: The following motion is repeated with the designated
conditions.
(During the motion, No. of Y reciprocation is displayed.)
a ) Y designated distance moving
b ) X designated distance moving, Move to Y starting position
9End
[END]
: Return to the motion starting position and execute capping to
end.
<Wiper motor test sequence>
No. Item Content Notice
1 Driving speed
designation
[], []: Selection of driving speed of the motor
Set value: 100 ~ 4000 pps (unit: 100 pps)
[], []:
Selection of item
1~3
2 WAIT designation [], []: Designating operation interval
Set value: 0~60 sec (unit: 1 sec)
3 Count designation [], []: Designating No. of operation times
Set value: CONTINUE, 1~1000 count (unit: 1 count)
4 Test start
[ENTER]
: Driving the motor with designated conditions
When CONTINUE is selected in count setting, finished with
[END]
5 Test end Wiper is returned to the original position.