Color Inkjet Printer JV33-130/160
2-32
WA R M I N G T ES T
Control test of the head warming heater ON/OFF is executed.
Note1: Temperature is displayed with a unit selected in the UNIT SETUP of the MACHINE SETUP function.
ACTION TEST
Operation of the following parts/units is tested.
<Warming test>
Item Content
TEMPERATURE Controlling the heater temperature with the temperature setting of the warming heater (each head).
Temperature and ON/OFF of each heater are displayed during the temperature control.
Set value (Celsius): OFF, 20 ~ 45 °C (unit: 1 °C)
Set value (Fahrenheit): OFF, 68 ~ 113 °F (as converted from celsius, unit is not 1°F)
<Action test>
Item Content
VACUUM FAN Contents: Operation test of vacuum fan motor
Set value: L.L, LOW, MID, HIGH, OFF
Y-CUTTER Contents: Operation test of media cutter.
Set value: UP, DOWN
Operation interval of Y-cutter is set with
[FUNCTION]
[], []: Operation interval setting
Set value: 0 ~ 7200 sec (unit: 1 sec)
[ENTER]
: UP, Down is repeated with set interval
Number count is displayed during the test.
HDC FAN 1&2 Contents: Operation test of HDC fan
Set value: ON, OFF
DEOD.FAN & DRY
FAN
Contents: Optional operation test of dryer/exhaust fan motor.
Set value: ON, OFF
LED POINTER Contents: Operation test of LED pointer.
Set value: ON, OFF