EasyManua.ls Logo

MIMAKI UJV100-160 - Cap Absorber Replacement

MIMAKI UJV100-160
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 Maintenance
106
4
Remove the cap.
Squeeze the lugs on either side of the cap and pull off.
5
Attach a new cap.
Position with the slot at the front and push in until it clicks.
6
Press the [ENTER] key once replacement is complete.
7
Close the front cover, then press the [ENTER] key.
Cap Absorber Replacement
If the cap absorber is very dirty or if ink drips on to the media, replace with a new cap absorber.
1
In LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
The Maintenance menu is displayed.
2
Select [Station] > [Carriage Out] > [Move To Platen Right End ], then press the [ENTER] key.
The carriage moves over the platen.
3
Turn off the power.
4
Open the front cover.

Table of Contents

Other manuals for MIMAKI UJV100-160

Related product manuals