Chapter 5 Dealing with Problems
128
Error
number
Message Cause Corrective action
b1d BaseIO PCB V24-A
b21 SLIDER1 PCB V3R3
A problem was detected with
the slider PCB power supply.
Turn off the power on the machine and
turn it on after a while. "Turning Off
the Power"(P. 31)
b22 SLIDER1 PCB V2R5
b23 SLIDER1 PCB V1R8
b24 SLIDER1 PCB V1R2
d09 HD MEMORY [1234]
A problem was detected with
head internal memory.
Turn off the power on the machine and
turn it on after a while. "Turning Off
the Power"(P. 31)
SYSTEM HALT
Error
number
Message Corrective action
000 Message
Turn off the power on the machine and turn it on after a while.
"Turning Off the Power"(P. 31)
406 WIPER ORG
1. Clean the wiper and around the wiper.
"Wiper Cleaning"(P. 88)
2. Turn off the power on the machine and turn it on after a while.
"Turning Off the Power"(P. 31)