Acoustic Output 17-1
17 Acoustic Output
This section of the operator’s manual applies to the overall system including the main unit,
probes, accessories and peripherals. This section contains important safety information
for operators of the device, pertaining to acoustic output and how to control patient
exposure through use of the ALARA (as low as reasonably achievable) principle. Also this
section contains information regarding the acoustic output testing and the real-time output
display.
Read this information carefully before using the system.
17.1 Concerns with Bioeffects
Diagnostic ultrasound is recognized as being safe. In fact, there have been no reports of
injuries to patients caused by diagnostic ultrasound.
It cannot be stated categorically that ultrasound is 100% safe. Studies have revealed that
ultrasound with extremely high intensity is harmful to body tissues.
Diagnostic ultrasound technology has made a great leap forward during the last several
years. This rapid advance has generated concerns about the potential risk of bioeffects
when new applications or diagnostic technologies become available.
17.2 Prudent Use Statement
Although there are no confirmed biological effects on patients caused by exposures from
present diagnostic ultrasound instruments, the possibility exists that such biological
effects may be identified in the future. Thus ultrasound should be used in a prudent
manner to provide medical benefit to the patient. High exposure levels and long exposure
times should be avoided while acquiring necessary clinical information.
17.3 ALARA Principle (As Low As
Reasonably Achievable)
It is required to practice ALARA when using ultrasound energy. Practicing ALARA ensures
that the total energy level is controlled below a low enough level at which bioeffects are
not generated while diagnostic information is being accumulated. The total energy is
controlled by output intensity and total radiation time. The output intensity necessary for
examinations differs depending on the patient and the clinical case.
Not all examinations can be performed with an extremely low level of acoustic energy.
Controlling the acoustic level at an extremely low level leads to low-quality images or
insufficient Doppler signals, adversely affecting the reliability of the diagnosis. However,
increasing the acoustic power more than necessary does not always contribute to an
increase in quality of information required for diagnosis, rather increasing the risk of
generating bioeffects.

Table of Contents

Other manuals for Mindray M7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray M7 and is the answer not in the manual?

Mindray M7 Specifications

General IconGeneral
TypePortable Ultrasound System
Display15-inch LCD
Imaging Modes2D, M-mode, Color Doppler, Power Doppler, Pulsed Wave Doppler, Continuous Wave Doppler
ProbesConvex, Linear, Phased Array
ApplicationsAbdominal, Cardiac, Vascular, OB/GYN, Small Parts, Musculoskeletal, Urology, Pediatric
BatteryRechargeable Lithium-ion
ConnectivityUSB, Ethernet, DICOM
Dimensions35 cm x 36 cm x 9 cm
Transducer Ports2 active transducer ports