Mindray WATO EX-65 - Service Manual

Mindray WATO EX-65
322 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
WATO EX-55/65 Anesthesia
Machine
Service Manual

Table of Contents

Other manuals for Mindray WATO EX-65

Questions and Answers

  • D
    DmitrySep 24, 2025
    How could I get pressure and volume curves out of tis device? In csv or any other reasonable format?

    Summary

    1 Safety

    1.1 Safety Information

    Provides crucial safety guidelines including dangers, warnings, cautions, and notes.

    1.2 Equipment Symbols

    Lists and explains various symbols used throughout the manual for equipment identification.

    2 Theory of Operation

    2.2 Gas Flow

    Details the gas flow principles and components within the anesthesia machine.

    2.2.1 Pneumatic Circuit Diagram

    Illustrates the pneumatic circuit diagram of the anesthesia machine.

    2.2.2 Parts List

    Lists all the parts included in the gas flow system with their corresponding numbers.

    3 Checkout and Test

    3.1 System Inspection

    Outlines the initial inspection procedures for the anesthesia machine before testing.

    3.2 Pipeline Tests

    Details the procedures for testing the integrity and function of the pipeline gas supplies.

    3.9 Alarm Tests

    Outlines the procedures for testing various alarms to ensure proper functionality.

    4 Maintenance and Calibration

    4.1 Equipment Maintenance

    Provides guidelines for routine maintenance and periodic replacement of parts.

    4.2 System Test

    Outlines essential tests to verify the normal operation and status of the anesthesia machine.

    4.3 System Calibration

    Details the procedures for calibrating various sensors and components of the anesthesia machine.

    5 Troubleshooting

    5.2 Technical Alarm Check

    Guides on checking and resolving technical alarms related to the ventilator and flowmeter.

    5.3 Pneumatic Circuit System Problems

    Details possible failures within the pneumatic circuit and their troubleshooting methods.

    5.5 Hardware and Electrical Problems

    Covers troubleshooting for hardware and electrical issues affecting the anesthesia machine's operation.

    6 Repair and Disassembly

    6.1 Prepare for Disassembly

    Lists tools and preparations required before starting the disassembly process.

    6.2 Disassemble the Assemblies

    Provides step-by-step instructions for disassembling various assemblies of the anesthesia machine.

    6.3 Disassemble the Breathing System

    Provides instructions for disassembling the breathing system components.

    7 Parts

    7.1 Main Unit

    Details the components and exploded views of the main unit.

    7.1.4 Display Assembly

    Details the exploded view and parts list for the display assembly.

    7.2 Breathing Circuit

    Lists components of the breathing circuit.

    Mindray WATO EX-65 Specifications

    General IconGeneral
    TypeAnesthesia Machine
    ModelWATO EX-65
    BrandMindray
    Tidal Volume Range20 to 1500 mL
    O2 Concentration21% to 100%
    I:E Ratio4:1 to 1:8
    Ventilation ModesVCV, PCV, SIMV, Manual, Spontaneous
    Flow MeterO2, N2O
    VaporizerUp to 2 vaporizers
    PEEP0 to 20 cmH2O
    Gas SupplyO2, N2O, Air
    MonitoringAirway Pressure, Flow, Volume
    O2 Flush35 to 75 L/min
    Respiratory Rate4 to 100 breaths per minute
    Power Supply100 to 240 VAC, 50/60 Hz
    Fresh Gas Flow0 to 15 L/min