3. Device description | 3.3 - Housing | 27
3.3.4.3 Plug-in cards
Product Description Position
PR 5310/20, ../21, ../
30, ../31
Analog output
Analog output 16Bits, 0/4-20mA
For more information see Chapter
Analog output.
Slot 1
PR 5310/23, ../24, ../
33, ../34
ProfiBus-DP- & Ana
log output
ProfiBus-DP-V0 Slave with 9,6kbit/s to
12Mbit/s, baud rate auto-detection
Analog output 16Bits, 0/4-20mA
For more information see Chapter
Analog output & Profibus-DP inter
face.
Slot 1
PR 5310/40, ../41, ../
50, ../51
ProfiBus-DP field
bus
ProfiBus-DP-V0 Slave with 9,6kbit/s to
12Mbit/s, baud rate auto-detection
For more information see Chapter
ProfiBus-DP interface.
Slot 1
PR 5310/60, ../61, ../
70, ../71
DeviceNet fieldbus
DeviceNet Slave with max.500kbit/s
For more information see ChapterDe
viceNet interface.
Slot 1
PR 5310/80, ../81, ../
90, ../91
EtherNet/IP fieldbus
EtherNet/IP with 10/100Mbit/s
For more information see ChapterEth
erNet/IP interface.
Slot 1
PR 5310/83, ../84, ../
93, ../94
ProfiNet I/O field
bus
ProfiNet I/O with 10/100Mbit/s
For more information see Chapter
ProfiNet I/O interface.
Slot 1