6. Operating | 6.2 - Configuration and adjustment via the keypad | 117
6.2.9 Configuring digital inputs
For each of the 3 inputs, an action can be defined for the signal change from
0to1(on) and from 1to0(off), see Chapter Defining actions.
For the signal change from 0to1(on) or from 1to0(off), the selected action
for each digital input can be linked with a condition that must be met. The
condition is selected from the selection list of conditions in ChapterSetting
conditions.
If [no condition] is selected, no condition is agreed. The action is then execut
ed directly.
SPM addresses for the limits, see ChapterSystem data.
Example:
Tare via the digital input only if the gross weight exceeds the limit.
1. Press and hold for 2–3 seconds.
SEtuP appears on the display.
2. Press "OK".
Cd 000 appears on the display (Cd flashes).
Input 1 on
3. Press (4×) to select dI 043.
4. Press "OK".
InP.1on appears on the display.
5. Press "OK".
Ion.ACt appears on the display.
6. Press "OK".
The action for the rising edge of input1 is defined (in this case, if the
input signal changes from 0to1, a tare command is triggered).
no.ACt appears on the display.
7. Press / to select the action b113=1, see Chapter Defining actions.
8. Press "OK".
Ion.Cnd appears on the display.
9. Press "OK".