EasyManua.ls Logo

Minebea Intec PR 5310 - Page 116

Minebea Intec PR 5310
200 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6. Operating | 6.2 - Configuration and adjustment via the keypad | 116
[Limit 3 off] LI 035 LIM.3oF
Input: Weight value under 3oF.VAL
Selection: Action under 3oF.ACt, see Chapter Defining actions
Selection: Condition under 3oF.Cnd, see Chapter Setting conditions
5. Press "Exit".
6. Save the settings.
6.2.8.2.1 Defining actions
Markers can be set for all limits (in this case, see Example 2 from Chapter
Configuring limits).
Define the action for the rising edge of the reference signal under
1on.ACt3on.ACt from the following list (in this case, marker 1 is set if 900kg
is exceeded).
An action for 1oF.ACt3oF.ACt can be defined accordingly.
Selection list for the actions
Action SPM bit Description
no act --- No function
b64 = 1 X64 = 1 Set marker 1
b65 = 1 X65 = 1 Set marker 2
b66 = 1 X66 = 1 Set marker 3
b64 = 0 X64 = 0 Clear marker 1
b65 = 0 X65 = 0 Clear marker 2
b66 = 0 X66 = 0 Clear marker 3
Note: The limit values can be assigned to the outputs directly in the I/O
parameters.

Table of Contents

Related product manuals