9. Fieldbus interface | 9.2 - Scale protocol | 156
9.2.5 Function numbers
Function numbers are written to MOSI by the master (SPS) and reflected in
MISO by the PR 5310.
Function number 0: I/O status bits (read), see ChapterFunction number
0: I/O status bits (read)
Function number 1: scale status (read), see ChapterFunction number 1:
scale status (read)
Function number 2: state-controlled action bits (read), see ChapterFunc
tion number 2: state-controlled action bits (read)
Function number 3: state of edge-controlled action bits (read), see Chap
terFunktion number 3: state of edge-controlled action bits (read)
Function number 4: calibration information, error byte (read), see Chap
terFunction number 4: adjustment information, error byte (read)
Function number 5: device type and software version (read), see Chapter
Function number 5: device type and software version (read)
Function number 6: serial number of the weighing point (read), see Chap
terFunction number 6: serial number of the weighing point (read)
Function numbers 8 to 22: weight data (read), see ChapterFunction num
ber 8–22: weight data (read)
Function numbers 24 to 29: Limit value (read/write), see ChapterFunction
number 24–29: Limit value (Read/Write)
Function numbers 30, 31: values of the current weighing point (read), see
ChapterFunction number 30, 31: Fixed values (Read/Write)
Function numbers 80 to 92: state-controlled action bits (write), see Chap
terFunction number 80–92: state-controlled action bits (write)
Function numbers 112 to 124: transition-controlled action bits (write),
see ChapterFunction number 112–124: transition-controlled action bits
(write)