EasyManua.ls Logo

Minebea Intec PR 5310 - Page 36

Minebea Intec PR 5310
200 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. Device installation | 4.3 - Hardware construction | 36
Technical data
Name Data
Internal connection
Pin strip,
28‑pin
External connection Plug connector, 6-pin
Switch cabinet device: screen connection on
the grounding terminal
Table-top device: screen connection in the
cable gland
Number of channels
6‑wire
or
4‑wire
Load cell supply U
DC
=12V, symmetrical to zero
(U
DC
=±6V, I
max
=160mA)
Capacity (number of load
cells)
≥75Ω, corresponding to 8load cells with
650Ω or 4load cells with 350Ω
Sense input U
DC
=±6V, with monitoring
Measurement input U
DC
=0…36mV, symmetrical to zero
Dead load suppression U
DC
=max.36mV(dead load + range)
Accuracy 0.2µV/d equivalent to 1.2mV for 6000d,
class III; according to OIMLR76/EN45501
Min. measuring signal (OIML) 0.1mV/V=1,2mV equivalent to 0.2µV/d @
6000d
Max. resolution 7.5million internal counts at 3mV/V (max.
3.356mV/V)
Linearity <0.003%
Temperature effect TK
0
<0.05 µV/K RTI,
<0.004%/10K @ 1mV/V
Temperature effect TK
Span
<±4.0ppm/K
Cable length Max. 300m
Cable type
6‑wire
with screen for entire cable and screen
for measurement cables, e.g., PR6135/..

Table of Contents