4. Device installation | 4.3 - Hardware construction | 64
Connection example for voltage output
Panel device Table-top device
①2,2kΩ /1kΩwith 24V/12V
②Screen
③Power supply unitU
DC
=24V0.5A
When the output is active (true), the output voltage drops from 24V/12V to
0V. The load resistance must be 2.2kΩ/1kΩ.