6 - 4
6. DISPLAY AND OPERATION
Name Symbol Unit Description
Display
range
Within one-revolution
position high
Cy2 100
pulse
The within one-revolution position is displayed in 100 pulse increments of
the encoder.
The value returns to 0 when it exceeds the maximum number of pulses.
The value is incremented in the CCW direction of rotation.
0
to
1310
Load inertia moment
ratio
dC Multiplier
(
1)
The estimated ratio of the load inertia moment to the servo motor shaft
inertia moment is displayed.
0.0
to
300.0
Bus voltage Pn V The voltage (across P-N) of the main circuit converter is displayed. 0
to
450
6.2.3 Changing the status display screen
The status display item of the servo amplifier display shown at power-on can be changed by changing the
parameter No.18 settings.
The item displayed in the initial status changes with the control mode as follows.
Control mode Status display at power-on
Position Cumulative feedback pulses
Position/
internal speed
Cumulative feedback pulses/servo motor speed
Internal speed Servo motor speed